2 test commissioning, Test commissioning, C 28) – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 28: 9400 highline | parameter setting & configuration

Advertising
background image

9400 HighLine | Parameter setting & configuration

Commissioning

Test commissioning

28

Firmware 1.37 - 09/2006

L

3.2

Test commissioning

Worksteps
Initial commissioning of motor/controller:

1.

Select motor in the »Engineer« motor catalog

.

(C 66)

• When the motor connected to the motor has an electronic nameplate (ENP), all motor data are

automatically read out of the ENP and a selection from the motor catalog is not required.

Read the

motor data out of the controller

(C 66)

2.

Accept/adapt route data

.

(C 69)

3.

Parameterise motor encoder

.

(C 70)

Save project and parameter set:

1.

Save parameter set

.

(C 57)

2. Save »Engineer« project.

Commissioning of the application:

Note:

The following steps require that the technology application "actuator – speed" has been selected in the

»Engineer« application catalog.

See chapter

Technology applications (TAs)

:

Commissioning using the »Engineer«

(C 235)

TA "Actuator – speed"

(C 244)

1. Enable controller via terminal RFR.
2. Enable setpoint follower via digital input DI2.
3. Define speed setpoint via analog input 1 (terminal AI1+/AI1-).
4. If required, the direction of rotation can be inverted via the digital input DI3.
5. Check further

Basic drive functions

of the applications:

A quick stop can be activated via the digital input DI1.

Quick stop (C 152)

A manual control is available for the setting-up operation.

Manual jog

(C 156)

• The enable is executed via the digital input DI6.

• The digital inputs DI7 and DI8 activate parameterisable setpoints for both directions of rotation.

Advertising