C02620, C02621, C02622 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 630: C02623, C02624, C02638, A quick deceleration, During the, Deceleration set, To the

Advertising
background image

9400 HighLine | Parameter setting & configuration

Parameter reference

Parameter list | C02620

630

Firmware 1.37 - 09/2006

L

C02620

C02621

C02622

C02623

C02624

C02638

Parameter | Name:

C02620 | Manual control speed 1

Data type: INTEGER_32

Index: 21955

d

= 55C3

h

Basic function "

Manual jog

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.0000

Unit/s

214748.3647 360.0000 Unit/s

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 10000

Parameter | Name:

C02621 | Manual control speed 2

Data type: INTEGER_32

Index: 21954

d

= 55C2

h

Basic function "

Manual jog

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.0000

Unit/s

214748.3647 720.0000 Unit/s

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 10000

Parameter | Name:

C02622 | Manual control acceleration

Data type: INTEGER_32

Index: 21953

d

= 55C1

h

Basic function "

Manual jog

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.0000

Unit/s²

214748.3647 360.0000 Unit/s²

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 10000

Parameter | Name:

C02623 | Manual control deceleration

Data type: INTEGER_32

Index: 21952

d

= 55C0

h

Basic function "

Manual jog

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.0000

Unit/s²

214748.3647 1440.0000 Unit/s²

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 10000

Parameter | Name:

C02624 | Manual control S-ramp time

Data type: UNSIGNED_32

Index: 21951

d

= 55BF

h

Basic function "

Manual jog

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.000

s

10.000 0.100 s

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 1000

Parameter | Name:

C02638 | Manual control status

Data type: INTEGER_32

Index: 21937

d

= 55B1

h

Status of the basic function "

Manual jog

" (LS_ManualJog).

Display range

(min. value | unit | max. value)

0

8

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT

Advertising