3 motor mounting direction, 4 configuration feedback, Motor mounting direction – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 38: Configuration feedback, 9400 highline | parameter setting & configuration

Advertising
background image

9400 HighLine | Parameter setting & configuration

Drive interface

Parameter setting

38

Firmware 1.37 - 09/2006

L

4.2.1.3

Motor mounting direction
Via the motor mounting direction list field (

C02527

) the direction of rotation can be

inverted depending on the motor mounting position, if required:

r

C02527

= "0": Clockwise motor ≡ positive machine direction.

r

C02527

= "1": Counter-clockwise motor ≡ positive machine direction.

4.2.1.4

Configuration feedback
In the most cases, the system only has one motor encoder, i.e. no separate position encoder

is installed on the load side. Motor position (angle of rotation) and motor speed are

detected via the motor encoder selected in

C00495

and converted with regard to the load

side.

[4-3]

Schematic diagram - feedback with position encoder = motor encoder

The actual position and speed values on the machine side result from the conversion via

the

Gearbox ratio

on the motor side and the

Feed constant

.

O

Tip!
Detailed information on parameter setting of the feedback systems for the motor

control can be found in chapter "

Encoder evaluation

".

(C 108)

n

Motor encoder

M

M

Œ

Œ

Advertising