Parameter | Name:

C00350 | CAN node address

Data type: UNSIGNED_8

Index: 24225

d

= 5EA1

h

• A change of the node address only gets active after a CAN reset node.

• The basic server channel RX/TX is automatically provided by the node address (

C00372

and

C00373

; subcode 1).

• Overwriting the value deactivates a possible node address selection entered by means of hardware.
Setting range

(min. value | unit | max. value)

Lenze setting

1

127 1

;

Read access ; Write access … CINH … PLC STOP … No transfer ; COM … MOT

Parameter | Name:

C00351 | CAN baud rate

Data type: UNSIGNED_8

Index: 24224

d

= 5EA0

h

• A change of the baud rate only gets active after a CAN reset node.

• Overwriting the value deactivates a possible node address selection entered by means of hardware.
Selection list

(Lenze setting printed in bold)

0 500 kbit/s
1 250 kbit/s
2 125 kbit/s
3 50 kbit/s
4 1 mbit/s
5 20 kbit/s
6 10 kbit/s
8 Reserved
9 Reserved

10 Reserved
11 Reserved
12 Reserved
13 Reserved
14 800 kbit/s
15 Reserved

255 Auto baud

;

Read access ; Write access … CINH … PLC STOP … No transfer ; COM … MOT

Parameter | Name:

C00352 | CAN slave/master

Data type: UNSIGNED_8

Index: 24223

d

= 5E9F

h

If "1" is entered and saved, the drive will start as CAN master after mains switching.
Selection list

(Lenze setting printed in bold)

0 Slave
1 Master

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT