C00055, C00056, C00057 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 549: C00058, C00059, C00060, Y set correctly in, C00058/1, C00055/1, C00055/2

Advertising
background image

L

Firmware 1.37 - 09/2006

549

9400 HighLine | Parameter setting & configuration

Parameter reference

Parameter list | C00055

C00055

C00056

C00057

C00058

C00059

C00060

Parameter | Name:

C00055 | Phase currents

Data type: INTEGER_32

Index: 24520

d

= 5FC8

h

Display range

(min. value | unit | max. value)

-500.00

A

500.00

Subcodes

Information

C00055/1

Zero phase-sequence system

C00055/2

Phase U

C00055/3

Phase V

C00055/4

Phase W

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 100

Parameter | Name:

C00056 | Torque setpoint

Data type: INTEGER_32

Index: 24519

d

= 5FC7

h

Display range

(min. value | unit | max. value)

-21474836.47

Nm

21474836.47

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 100

Parameter | Name:

C00057 | Torque

Data type: UNSIGNED_32

Index: 24518

d

= 5FC6

h

Display range

(min. value | unit | max. value)

0.000

Nm

2147483.647

Subcodes

Information

C00057/1

Maximum torque

C00057/2

Torque at maximum current (

C00022

)

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 1000

Parameter | Name:

C00058 | Rotor displacement angle

Data type: INTEGER_32

Index: 24517

d

= 5FC5

h

Setting range

(min. value | unit | max. value)

-179.9

°

179.9

Subcodes

Lenze setting

Information

C00058/1

-90.0 °

Rotor displ. angle resolver

C00058/2

0.0 °

Rotor displ. angle encoder

C00058/3

0.0 °

Rotor displ. angle module

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM ; MOT Scaling factor: 10

Parameter | Name:

C00059 | Motor - pole pair number

Data type: UNSIGNED_32

Index: 24516

d

= 5FC4

h

Display range

(min. value | unit | max. value)

0

200

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00060 | Rotor position

Data type: INTEGER_32

Index: 24515

d

= 5FC3

h

Display range

(min. value | unit | max. value)

0

2047

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT