2 virtual clutch, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 310

Advertising
background image

9400 HighLine | Parameter setting & configuration

TAs for interconnection via electrical shaft

TA "Electronic gearbox" | Operating mode "Electronic gearbox"

310

Firmware 1.37 - 09/2006

L

12.2.5.2

Virtual clutch

[12-14] Function "Virtual clutch" in the signal flow (schematic diagram)

r

Parameter setting: Tab Application parameter  Dialog level Overview  Electronic

gearbox  Virtual clutch

r

Configuration: Tab FB editor  FB ClutchElectricalShaft

n

Master value with stretch factor

o

Master value with clutch

M

v

Slave

Real master/

Virtual master

v

t

Dv

C03006 = 0

Œ



Parameters

Lenze setting

Value Unit

C03673

Master value with stretch factor

- Unit/t

C03021

Activate clutch

Deactivated

C03665/1

Clutch in ramp

1.000 s

C03665/2

Decoupling ramp

1.000 s

C03665/3

Stop ramp

1.000 s

C03668

Jerk limitation

1.000 s

C03674

Master value with clutch

- Unit/t

Control inputs of the function

Signal configuration

Lenze setting

Control input

(Multiplexer parameters)

DigIn 4  Close clutch

C03058/12

FALSE  Clutch - positive opening operation

C03058/13

Advertising