2 function description – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 417

Advertising
background image

L

Firmware 1.37 - 09/2006

417

9400 HighLine | Parameter setting & configuration

Oscilloscope

Function description

14.2

Function description

With an online connection to the controller, use the oscilloscope user interface of the

»Engineer« to set the trigger condition and the sample rate and select the variables to be

recorded.
When the measurement is started, the set parameters are transferred to the controller and

checked. If invalid settings are found, the oscilloscope sends an error. Otherwise, the

measurement is started.
With an online connection, the measured controller data are transferred to the »Engineer«

and graphically represented on the oscilloscope user interface as soon as the measurement

has been completed.

Recording variable values
The operating system scans the oscilloscope in fixed 1 ms-cycles, i.e. the oscilloscope can

record variable values with a sample rate of max. 1 kHz.

Recording system variable values of the internal motor control
Unlike the variables declared in the application, the system variables of the internal motor

control (MCTRL) can also be recorded with a sample rate higher than 1 kHz.

Recording I/O variable values referring to a task
When selecting the variables to be measured, it is possible to indicate a task reference for

the variables. If the behaviour of a certain task is to be examined, you can indicate the task

reference to exactly record the values valid for the task run-time.

r

The variable values are recorded during the process output image generation of the

task.

Note!

In the servo operating modes, recordings with a time-based resolution of 31.25

μs and 125 μs are not possible!