Basic drive functions

Brake control | Parameter setting

9.11.1.6

Torque feedforward control
The motor control serves to precontrol the required torque of the drive when the brake is

released. Here it must be ensured that the position controller is switched off and the speed

setpoint is loaded with the actual value (no additional torque via the P component of the

speed controller).

Via

C02588

it is selected whether a parameterised starting torque or the torque

memorised during the last closing operation shall be used for the feedforward control.

Feedforward control with parameterised starting torque

[9-15] Feedforward control with parameterised starting torque

Application example:
A hoist drive is to be operated with different loads. Unfortunately we do not know when

the load is available, but the starting direction (lifting or lowering) is known.

r

In a no-load condition, the hoist drive needs a torque of 10 Nm. For holding the

maximum load it needs a torque of 50 Nm.

r

The change-over between lifting and lowering at start-up is done via the input

BRK_bStartingTorque2.

Note!

The torque is precontrolled for one second. During this time, the actual torque

must have reached 90 % of the set torque, otherwise a fault is tripped!

n

C02586

: Starting torque 1

o

C02587

: Starting torque 2

p

C02588

: Waiting torque source

r

When

C02588

= 0, a change-over

between two starting torques is

possible via input

BRK_bStartingTorque2:
BRK_bStartingTorque2 = FALSE:

Starting torque 1 (

C02586

) is used.

BRK_bStartingTorque2 = TRUE:

Starting torque 2 (

C02587

) is used.

1

0

BRK_bStartingTorque2

C02586

Œ


C02587

1

0

C02588 = 0

Ž

S&H

CTRL

Speed controller