6 manual jog, Directions of rotation, Manual jog – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 256: C 256), Manual jog (c 256), 9400 highline | parameter setting & configuration, Standard tas ta "actuator – speed" | manual jog

Advertising
background image

9400 HighLine | Parameter setting & configuration

Standard TAs

TA "Actuator – speed" | Manual jog

256

Firmware 1.37 - 09/2006

L

11.2.6

Manual jog

[11-9] Basic function "Manual jog" (schematic diagram)

For the setting-up operation the basic function "Manual jog" is available. It is requested via

the digital input DI6. If no other basic function and error status are active, enable is carried

out and the manual jog via the inputs DI7 and DI8 is possible.

r

Parameter setting: Tab Application parameter  Dialog level Overview  Manual jog

O

Tip!
Detailed information on the manual jog function can be found in chapter "Basic

drive functions"  subchapter "

Manual jog

".

(C 156)

LS_ManualJog

n

t

и

з

LS_Brake

n

t

LS_Limiter

n

t

LS_Quickstop

STOP

Gain

Invert setpoint

Selection

LS_Speed...

M

Speed
setpoint

n

t

LS_Stop

internal
status machine

DI2

DI6

DI7

DI8

DI1

DI3

DI4

OUT

IN

Ramp generator

%

1

%

2

%

15

Fixed setpoints

Status

machine

(basic drive

functions)

Speed setpoint

Basic drive functions

AIN1

M

v

и
з

Parameters

Lenze setting

Value Unit

C02620

Manual jog speed 1

360.0000 Unit/s

C02621

Manual jog speed 2

720.0000 Unit/s

C02622

Manual acceleration

360.0000 Unit/s

2

C02623

Manual deceleration

1440.0000 Unit/s

2

C02624

Inaccuracy time of manual traversing

0.100 s

Control inputs of the function

Signal configuration

Lenze setting

Control input

(Multiplexer parameters)

DigIn 6  Request manual jog

C03155/1

DigIn 7  Activate positive manual jog

C03155/2

DigIn 8  Activate negative manual jog

C03155/3

FALSE  Activate 2. speed

C03155/4

Advertising