Diagnostics & error analysis

Error messages of the operating system

Negative limit switch has tripped [0x00b80002]

Motor brake: Angular drift with closed brake is too large [0x00b80003]

Motor brake: Automatically activated when the waiting time has elapsed [0x00b80004]

Motor brake: Status monitoring error [0x00b80005]

Response (Lenze setting printed in bold)

…

None … System fault : Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

The

travel range limit switch

in negative traversing

direction has tripped.

Reset error message and

retract limit switch

.

Response (Lenze setting printed in bold)

…

None … System fault : Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

Despite the applied brake, the stop position of the motor

axis has changed by more than the permissible angle of

rotation set in

C02595

.

• Deactivate standstill monitoring (

C02595

= 0).

• Increase waiting time for status monitoring (

C02591

).

The standstill monitoring only starts after this

waiting time has elapsed.

• Increase brake closing time (

C02589

) since during the

brake closing time the standstill monitoring is not

active.

• Reduce threshold for brake activation (

C02581

).

Response (Lenze setting printed in bold)

…

None … System fault : Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

This time monitoring will only be active if the speed

setpoint has reached the threshold for brake activation

(

C02581

).

If the actual speed value does not reach/fall below the

threshold set in

C02581

within the parameterised

waiting time for brake activation (

C02593

), the brake will

be closed due to time-out.

• Increase waiting time for brake activation (

C02593

).

• Reduce threshold for brake activation (

C02581

).

Response (Lenze setting printed in bold)

…

None … System fault : Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

Faulty external feedback of the brake status to the brake

control.

• Check brake configuration with regard to the control

selection in

C02580

.

• Check setting for status input monitoring in

C02583

.

When monitoring is active, the bBrakeApplied input

must be triggered correctly (bBrakeApplied =

bBrakeReleased).

• Check voltage supply of the brake module.

Advertising