C00159, C00166, C00167 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 559: C00168, C00169, C00171, Is shown bit-coded in, Internal history buffer, 9400 highline | parameter setting & configuration

Advertising
background image

L

Firmware 1.37 - 09/2006

559

9400 HighLine | Parameter setting & configuration

Parameter reference

Parameter list | C00159

C00159

C00166

C00167

C00168

C00169

C00171

Parameter | Name:

C00159 | Quick stop by (source)

Data type: BITFIELD_16

Index: 24416

d

= 5F60

h

Value is bit-coded:

Bit 0 Reserved
Bit 1 Reserved
Bit 2 Reserved
Bit 3 Reserved
Bit 4 Application
Bit 5 Controller command
Bit 6 Error response
Bit 7 Internal PLC
Bit 8 Reserved
Bit 9 Reserved

Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00166 | Error status

Data type: VISIBLE_STRING

Index: 24409

d

= 5F59

h

Error message for error number indicated in

C00168

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00167 | Service code

Data type: VISIBLE_STRING

Index: 24408

d

= 5F58

h

This code is used internally by the controller and must not be overwritten by the user!

Parameter | Name:

C00168 | Error number

Data type: UNSIGNED_32

Index: 24407

d

= 5F57

h

Display of the error number of the first error with highest priority
Display range

(min. value | unit | max. value)

0

4294967295

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00169 | Logbook event filter

Data type: UNSIGNED_32

Index: 24406

d

= 5F56

h

Bit coded word for the filtering of system events (fault, warning, info)

• A set filter bit inhibits entry into the log file.
Setting range

(min. value | unit | max. value)

Lenze setting

0

4294967295 0

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00171 | Service code

Data type: UNSIGNED_32

Index: 24404

d

= 5F54

h

This code is used internally by the controller and must not be overwritten by the user!