9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 107

Advertising
background image

L

Firmware 1.37 - 09/2006

107

9400 HighLine | Parameter setting & configuration

Motor interface

System block "LS_MotorInterface"

MI_dnActualMotorTorque_n

DINT

Current motor torque

• 100 % ≡

C00057/2

• Display in

C00774

in [Nm]

Signal flow - motor interface (C 95)

MI_dnActualMotorSpeed_n

DINT

Current speed of the motor shaft in [%]

• 100 % ≡ Motor reference speed (

C00011

)

Signal flow - encoder evaluation (C 109)

MI_dnActualMotorSpeed_s

DINT

Current speed of the motor shaft in [rpm]

• Display under

C00772

Signal flow - encoder evaluation (C 109)

MI_dnActualMotorPos_p

DINT

Current position of the motor shaft in [increments]

• Display under

C00770

Signal flow - encoder evaluation (C 109)

MI_-

dnActualDCBusVoltage_n

DINT

Actual DC-bus voltage

• 100 % ≡ 1000 V

Signal flow - motor interface (C 95)

MI_dnThermalLoadDevice_n

DINT

Thermal device utilisation in [%]

• Current result of the Ixt calculation.

MI_dnThermalLoadMotor_n

DINT

Thermal motor utilisation in [%]

• Current result of the I

2

xt calculation.

Output

DIS code | Data type

Value/meaning

Advertising