9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 392

Advertising
background image

9400 HighLine | Parameter setting & configuration

TAs for positioning tasks

TA "Multi-purpose positioning" | Profile data management

392

Firmware 1.37 - 09/2006

L

S-ramp time

When the S-ramp time is selected for a profile, it is executed with S-shaped ramps, e.g. acceleration and

deceleration processes are started smoothly to reduce the jerk and thus prevent the drive components

from damage.

• The acceleration/deceleration specified in the profile are only reached after the defined S-ramp time

has elapsed.

• This type of acceleration/deceleration is required for e.g. sensitive machine parts with clearance.

• The slower acceleration increase with the S profile prolongs the positioning time compared to the

time optimal L profile.

n

without jerk limitation (L profile)

o

with jerk limitation (S profile)

Final speed

Selection of the speed by which the drive is to start the next profile after reaching the target position.

"Velocity changeover" or "Overchange" can be implemented with a final speed that is non-zero, i.e.

when the target position is reached, a second positioning process is started immediately without the

drive being decelerated to standstill at the first target position:

n

Target position

o

Final speed (here non zero)

Start of TP window / End of TP window

These profile parameters serve to restrict the range for a touch probe positioning (residual path

positioning) in which touch probes are to be detected.
Sequence profile with TP

Profile data set (profile no. 1 ... 100) in which the profile data of the profile are stored which is to be

executed after a touch probe has been detected.

• For the setting "0" no further profile connection by touch probe is effected.
Sequence profile without TP

Profile data set (profile no. 1 ... 100) in which the profile data of the profile is stored which is to be

executed after the standard profile has been executed (profile chaining).

• With the setting "0" no profile chaining is carried out.

• The sequence profile defined in this profile parameter is executed even if no touch probe has been