L

Firmware 1.37 - 09/2006

215

9400 HighLine | Parameter setting & configuration

Basic drive functions

Brake control | Parameter setting

9.11.1.4

Brake activation in automatic operation

Brake activation through N < N

min

[9-10] Process of brake activation through N < Nmin

O

Tip!
The value at

C02581

is to be set to approx. 5 ... 20 % of the maximum speed to

minimise the wear of the brake and provide for an optimum brake response by a

low grinding of the brake.



speed setpoint



actual speed value

n

C02581

: Brake activation threshold

r

If the motor speed falls below the

threshold for brake activation set in

C02581

, the brake is automatically

triggered to close in the automatic

operation (mode 2/12).

r

Here, only the absolute value of the

motor speed is considered, the

direction of rotation is disregarded.

t

t

Œ

t

0

1

n

Standstill

BRK_bReleaseBrakeOut

t

Stopping