2 parameter setting, 3 reconfiguring analog input 1 as a current input, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 118

Advertising
background image

9400 HighLine | Parameter setting & configuration

I/O terminals

Analog inputs

118

Firmware 1.37 - 09/2006

L

7.2.2

Parameter setting

Short overview of parameters for the analog inputs:

7.2.3

Reconfiguring analog input 1 as a current input

Proceed as follows to reconfigure analog input 1 as a current input:

1. Bridge terminals A1R and A1 on terminal strip X3 by means of wiring.
2. Select the corresponding current loop under

C00034

.

O

Tip!
In this way, you can implement a 4 ...20 mA current loop, e.g. for speed setpoint

selection.

Open-circuit monitoring
Under

C00598

, you can select an error response to an open circuit for the 4 ...20 mA current loop.

Parameter

Information

C00034

Config. analog input 1

C00598

Resp. to open circuit AIN1

C02730/1

AIN1: Gain

C02730/2

AIN2: Gain

C02731/1

AIN1: Offset

C02731/2

AIN2: Offset

C02732/1

AIN1: Dead band

C02732/2

AIN2: Dead band

C02800/1

AIN1: Input signal (-16384 ≡ -100 %, 16383 ≡ 100 %)

C02800/2

AIN2: Input signal (-16384 ≡ -100 %, 16383 ≡ 100 %)

Highlighted in grey = display parameter

Advertising