C02586, C02587, C02588 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 626: C02589, C02590, C02591, Time set in, When, 50 nm, And the "waiting time for

Advertising
background image

9400 HighLine | Parameter setting & configuration

Parameter reference

Parameter list | C02586

626

Firmware 1.37 - 09/2006

L

C02586

C02587

C02588

C02589

C02590

C02591

Parameter | Name:

C02586 | Starting torque 1

Data type: INTEGER_32

Index: 21989

d

= 55E5

h

Basic function "

Brake control

"

Setting range

(min. value | unit | max. value)

Lenze setting

-21474836.47

Nm

21474836.47 0.00 Nm

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 100

Parameter | Name:

C02587 | Starting torque 2

Data type: INTEGER_32

Index: 21988

d

= 55E4

h

Basic function "

Brake control

"

Setting range

(min. value | unit | max. value)

Lenze setting

-21474836.47

Nm

21474836.47 0.00 Nm

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 100

Parameter | Name:

C02588 | Starting torque source

Data type: UNSIGNED_32

Index: 21987

d

= 55E3

h

Basic function "

Brake control

"

Selection list

(Lenze setting printed in bold)

0 Starting torque 1/2
1 Stopping value

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C02589 | Brake closing time

Data type: UNSIGNED_32

Index: 21986

d

= 55E2

h

Basic function "

Brake control

"

Setting range

(min. value | unit | max. value)

Lenze setting

0

ms

60000 100 ms

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C02590 | Brake opening time

Data type: UNSIGNED_32

Index: 21985

d

= 55E1

h

Basic function "

Brake control

"

Setting range

(min. value | unit | max. value)

Lenze setting

0

ms

60000 100 ms

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C02591 | Waiting time- status monitoring

Data type: UNSIGNED_32

Index: 21984

d

= 55E0

h

Basic function "

Brake control

"

Setting range

(min. value | unit | max. value)

Lenze setting

0

ms

60000 100 ms

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Advertising