C00582, C00583, C00584 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 589: C00585, Action set in, Ptc temperature in, Instead, 9400 highline | parameter setting & configuration

Advertising
background image

L

Firmware 1.37 - 09/2006

589

9400 HighLine | Parameter setting & configuration

Parameter reference

Parameter list | C00582

C00582

C00583

C00584

C00585

Parameter | Name:

C00582 | Resp. to heatsink temp. > C00122

Data type: UNSIGNED_32

Index: 23993

d

= 5DB9

h

Response, if heatsink temperature > variable limit temperature (

C00122

)

Selection list

(Lenze setting printed in bold)

0 No response
1 Error
5 Warning

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00583 | Resp. to motor overtemp. KTY

Data type: UNSIGNED_32

Index: 23992

d

= 5DB8

h

Response, if motor temperature > fixed limit temperature
Selection list

(Lenze setting printed in bold)

0 No response
1 Error
5 Warning

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM ; MOT

Parameter | Name:

C00584 | Resp. to motor temp. > C00121

Data type: UNSIGNED_32

Index: 23991

d

= 5DB7

h

Response, if motor temperature > variable limit temperature (

C00121

)

Selection list

(Lenze setting printed in bold)

0 No response
1 Error
5 Warning

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM ; MOT

Parameter | Name:

C00585 | Resp. to motor overtemp. PTC

Data type: UNSIGNED_32

Index: 23990

d

= 5DB6

h

Response, if motor temperature above PTC input T1/T2 too high
Selection list

(Lenze setting printed in bold)

0 No response
1 Error
5 Warning

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM ; MOT

Advertising