4 monitoring, 1 setting the error response, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 439

Advertising
background image

L

Firmware 1.37 - 09/2006

439

9400 HighLine | Parameter setting & configuration

Diagnostics & error analysis

Monitoring

15.4

Monitoring

The controller includes different monitoring functions that protect the drive against

impermissible operating conditions.

r

If a monitoring function responds,
– an entry will be made into the

Logbook

of the controller,

– the response (quick stop by trouble, warning, fault, etc.) selected for the monitoring

function will be activated,

– the status of the internal device control changes according to the selected response,

controller inhibit is set, and the "DRIVE ERROR" LED on the front of the controller goes

on:

See also:

LED status displays

(C 34)

Device states

(C 45)

15.4.1

Setting the error response

When a monitoring function is addressed, the response set for this monitoring function

(quick stop by trouble, warning, fault, etc.) will be activated.

r

For many monitoring functions the response can be individually parameterised via

parameters.

Response

Logbook entry

Display under

C00168

Pulse inhibit

Controller inhibit

Acknowledgeme

nt required

LED

"DRIVE ERROR"

None

OFF

Fault

;

;

;

;

;

Trouble

;

;

;

;

(after 0.5 s)

Quick stop by

trouble

;

;

;

Warning locked

;

;

;

Warning

;

;

Information

;

OFF

System error

;

;

;

;

Mains

switching

is required!

Advertising