C02527, C02528, C02529 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 616: T field, The direct, 0": clockwise motor, 1": counter-clockwise motor, Serves to define, Hen the traversing range, 9400 highline | parameter setting & configuration

Advertising
background image

9400 HighLine | Parameter setting & configuration

Parameter reference

Parameter list | C02527

616

Firmware 1.37 - 09/2006

L

C02527

C02528

C02529

Parameter | Name:

C02527 | Motor mounting direction

Data type: UNSIGNED_32

Index: 22048

d

= 5620

h

Drive interface

Selection list

(Lenze setting printed in bold)

0 Motor rotating CW
1 Motor rotating CCW

;

Read access ; Write access ; CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C02528 | Traversing range

Data type: UNSIGNED_32

Index: 22047

d

= 561F

h

Drive interface

Selection list

(Lenze setting printed in bold)

0 Unlimited
1 Limited
2 Modulo

;

Read access ; Write access ; CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C02529 | Load sensor mounting direction

Data type: UNSIGNED_32

Index: 22046

d

= 561E

h

Drive interface

Selection list

(Lenze setting printed in bold)

0 Sensor rotating CW
1 Encoder rotating CCW

;

Read access ; Write access ; CINH … PLC STOP … No transfer … COM … MOT