C00388, C00390, C00391 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 581: C00392, 9400 highline | parameter setting & configuration

Advertising
background image

L

Firmware 1.37 - 09/2006

581

9400 HighLine | Parameter setting & configuration

Parameter reference

Parameter list | C00388

C00388

C00390

C00391

C00392

Parameter | Name:

C00388 | CAN node guarding status

Data type: UNSIGNED_8

Index: 24187

d

= 5E7B

h

Selection list

(display only)

0 Unknown
4 Stopped
5 Operational

127 Pre-operational

Subcodes

Information

C00388/1

Status node 1 ... 32

C00388/...
C00388/32

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00390 | CAN error register (DS301V402)

Data type: BITFIELD_8

Index: 24185

d

= 5E79

h

CAN error register according to DS301V402
Value is bit-coded:

Information

Bit 0 Generic error

Currently only bit 0 and bit 4 contain the corresponding

information.

Bit 1 Current error (not used)
Bit 2 Voltage error (not used)
Bit 3 Temperature error (not used)
Bit 4 Communication error
Bit 5 Device profile-spec. error (not used)
Bit 6 Reserved
Bit 7 Manufacturer-spec. error (not used)

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00391 | CAN emergency object

Data type: BITFIELD_32

Index: 24184

d

= 5E78

h

Identifier of the emergency telegram

• Setting bit 31 of this code (0x8nnnnnnn) deactivates the generation of emergency telegrams.
Value is bit-coded:

Information

Bit 0 COB-ID bit 0

• Bit 0 ... 10: COB-ID

• Bit 11 ... 30: Reserved

• Bit 31: Emergency stop

... ...

Bit 31 Emergency inactive/active

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00392 | CAN emergency delay time

Data type: UNSIGNED_16

Index: 24183

d

= 5E77

h

Minimum time between two successive emergency telegrams.

• Setting "0" deactivates the inhibit time check.

• The inhibit time is entered in 1/10 ms. The code automatically rounds the entries down to the preceding full

millisecond.

Setting range

(min. value | unit | max. value)

Lenze setting

0

65535 0

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT