Parameter list | C00177

C00177

C00178

C00179

C00180

C00181

C00183

Parameter | Name:

C00177 | Service code

Data type: UNSIGNED_32

Index: 24398

d

= 5F4E

h

This code is used internally by the controller and must not be overwritten by the user!

Parameter | Name:

C00178 | Elapsed-time meter

Data type: UNSIGNED_32

Index: 24397

d

= 5F4D

h

Display range

(min. value | unit | max. value)

0

s

4294967295

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00179 | Power-on time meter

Data type: UNSIGNED_32

Index: 24396

d

= 5F4C

h

Display range

(min. value | unit | max. value)

0

s

4294967295

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00180 | Service code

Data type: VISIBLE_STRING

Index: 24395

d

= 5F4B

h

For Lenze service only

;

Read access ; Write access … CINH … PLC STOP ; No transfer … COM … MOT

Parameter | Name:

C00181 | Red. brake chopper threshold

Data type: UNSIGNED_32

Index: 24394

d

= 5F4A

h

Setting range

(min. value | unit | max. value)

Lenze setting

0

V

100 0 V

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00183 | Device state

Data type: UNSIGNED_32

Index: 24392

d

= 5F48

h

Display of the device state for controller diagnostics.
Selection list

(display only)

0 Operation
1 Operation/Warning active
2 Operation/warning locked active
3 Operation/Quick stop active
4 Operation/Application stopped

10 Initialisation active
20 System error active
90 Drive switched on
91 Device switched-on/QSP fault

101 Safe torque off active
102 Error active
104 Trouble active
141 Drive ready to start
151 Quick stop by trouble active

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT