6 motor replacement, Motor replacement, C 33) – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 33: 9400 highline | parameter setting & configuration

Advertising
background image

L

Firmware 1.37 - 09/2006

33

9400 HighLine | Parameter setting & configuration

Commissioning

Motor replacement

3.6

Motor replacement

Scenario: The motor has failed in a running system.

Note!

In the following procedure described we assume that the controller is not

affected by the failure.

Worksteps
Replacement of the motor:

1. Replace the motor.

See Mounting Instructions for the controller!

Note:

The motor connection at the controller can be accessed without pulling the basic device out of the

installation backplane.

For a motor with an electronic nameplate (ENP):

1. Restart controller with connected motor to read out the motor data from the electronic nameplate.

• Restart the controller either by switching off and on again the voltage supply or by the device

command "Restart controller" (

C00002

= "11000").

• See chapter

Motor interface Read the motor data out of the controller

(C 66)

2.

Save parameter set

.

(C 57)

For a motor without an electronic nameplate (ENP):

Note:

The motor is operated with the motor and route data that are stored on the memory module.

• See chapter

Motor interface Initial commissioning

(C 65)

1. If required, detect rotor displacement angle.

Set rotor displacement angle

(C 71)

• Required for synchronous motors of an original equipment manufacturer and Lenze synchronous

motors with Stegmann absolute value encoder.

2.

Save parameter set

.

(C 57)

Advertising