9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 175

Advertising
background image

L

Firmware 1.37 - 09/2006

175

9400 HighLine | Parameter setting & configuration

Basic drive functions

Homing | System block "LS_Homing"

Outputs

Identifier

DIS code | data type

Value/meaning

HM_dnState

C02657

| DINT

Status (bit-coded)

• When the basic function is not enabled, all bits are set to "0".

• Bits which are not listed are not assigned with a status (always "0").

Bit 1 Reference search is active.
Bit 2 Reference search is completed.
Bit 3 Acceleration/deceleration phase is active.
Bit 5 CCW rotation is active.
Bit 7 Reference is known

Bit 15 Error in basic function active (group signal).
Bit 16 Pre-stop (home switch) has been detected.
Bit 17 Touch probe/zero pulse has been detected.
Bit 21 Profile data are limited by basic function "

Limiter

".

Bit 22 Traversing direction is inhibited by basic function "

Limiter

".

Bit 23 Abort by basic function "

Limiter

".

Bit 25 Stopping is active.

(Homing is enable but not active or speed ≠ 0)

Bit 30 Profile generation error.

HM_bEnabled

C02659/6

| BOOL

Status output "Basic function is enabled"

TRUE Homing via the control inputs is possible.

• The enable input HM_bEnable is set to TRUE and the controller is

in the function state "Homing active".

HM_bActive

C02659/7

| BOOL

Status output "Basic function is active"

TRUE Reference search is active (the drive axis is moving).

HM_bDone

C02659/8

| BOOL

Status output "Basic function is completed"

TRUE Reference search is completed.

• Output is reset to FALSE when input HM_bActivateHoming is

reset to FALSE.

HM_bHomePosAvailable

C02659/9

| BOOL

Status output "Reference is known"

TRUE The drive knows the home position.