TA "Actuator – speed" | Assignment of the I/O terminals

246

Firmware 1.37 - 09/2006

L

11.2.2

Assignment of the I/O terminals

11.2.2.1

Setpoint and control signals
The following tables contain the Lenze assignment of the analog and digital inputs for the

technology application "actuator – speed".

Analog inputs

Digital inputs

Terminal X3

Signal (Lenze setting)

AI1-

AI1+

Speed setpoint

Speed setpoint conditioning (C 250)

AI2-

AI2+

-

I/O terminals Analog inputs (C 117)

Terminal X5

Signal (Lenze setting)

DI1

Quick stop

• If DI1 is set to LOW level, the drive is decelerated to standstill within the deceleration

time set for the quick stop function independent of the setpoint selection.

• If the quick stop function is deactivated, the drive is led to the selected setpoint again via

the set acceleration time.

Quick stop (C 257)

DI2

Enable speed follower

Speed follower (C 255)

DI3

Invert speed setpoint

Setpoint inversion (C 252)

DI4

Activate fixed setpoint 1

• Instead of the selection via the analog input 1 the fixed setpoint 1 is used as speed

setpoint.

Change-over to fixed setpoint (C 251)

DI5

Reset error

• By means of a LOW-HIGH edge an existing error status can be reset if the cause of the

fault is removed.

DI6

Manual jog

Manual jog (C 256)

DI7

DI8

Function

LOW

LOW

Stop

HIGH

LOW

Manual control in positive direction

LOW

HIGH

Manual control in negative direction

HIGH

HIGH

- (previous state remains active)

I/O terminals Digital inputs (C 123)

A1+

A1-

A1-

A1R

A2+

A2-

GI

RFR

DI1

DI2

DI3

DI4

DI5

DI6

DI7

DI8