2 executing manual jog, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 158

Advertising
background image

9400 HighLine | Parameter setting & configuration

Basic drive functions

Manual jog | Executing manual jog

158

Firmware 1.37 - 09/2006

L

9.4.2

Executing manual jog

Requirements

r

The controller is in the device state "Operation".

r

The basic function "manual jog" is part of the active application.

r

No other basic function is active.

Activation
To request the control via the basic function, the enable input MAN_bEnable in the

application must be set to TRUE.

r

If no other basic function is active, it is changed to the function state "Manual jog

active" and manual jog can be executed via the control inputs.

r

A successful change to the function state "Manual jog active" is displayed by a TRUE

signal at the status output MAN_bEnabled.

Deactivation
If the enable input MAN_bEnable is reset to FALSE, an active manual jog is reset, i.e. the

control inputs for manual jog are inhibited and the drive is braked to standstill within the

deceleration time for

Standard stop

.

(C 148)

r

The status output MAN_bEnabled is reset to FALSE and a changeover from the active

function state "Manual jog active" via the function state "Drive is stopped" back to th

basic state "Drive in standstill" is effected.

Advertising