2 mode 0: brake control is switched off, 3 mode 1/11: direct control of the brake, Mode 0: brake control is switched off – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 222: C 222), Mode 1/11: direct control of the brake

Advertising
background image

9400 HighLine | Parameter setting & configuration

Basic drive functions

Brake control | Mode 0: Brake control is switched off

222

Firmware 1.37 - 09/2006

L

9.11.2

Mode 0: Brake control is switched off

If the mode 0 is selected in

C02580

, the brake activation is switched off.

r

If a brake module is available, it will not be triggered.

r

The brake monitoring function is not active.

r

If a fault is reported by the brake control, it will be reset.

r

The output signals of the system block LS_Brake are reset:
BRK_dnState = 0
BRK_bReleaseBrakeOut = FALSE
BRK_bBrakeReleased = FALSE
BRK_bError = FALSE

9.11.3

Mode 1/11: Direct control of the brake

If the mode 1 or 11 has been selected in

C02580

, the brake is directly controlled via the

input BRK_bReleaseBrake.

O

Tip!
Mode 1/11 can be used to easily check if the brake switches correctly.

r

At the same time, the selection of the mode defines the type of brake control:
– Mode 1: Direct brake control via brake module.
– Mode 11: Direct brake control via a digital output.

r

Setting the pulse inhibit or controller inhibit does not influence the output signal.

r

After the brake has been activated and the brake closing time has elapsed, the

controller inhibit is set automatically by the basic function "brake control".

r

For the operation with the brake module (mode 1) the required polarity for brake

control can be set in

C02585

.

Note!

The mode 0 is preset in the Lenze setting to reach a safe status after mains

connection.