Parameter | Name:

C00586 | Resp. to resolver open circuit

Data type: UNSIGNED_32

Index: 23989

d

= 5DB5

h

Response to open circuit in resolver

For the use of the resolver as motor encoder: If an error occurs, the safe operation of the motor is no longer

ensured, therefore for safety reasons always the "Error" response should be set!

Selection list

(Lenze setting printed in bold)

0 No response
1 Error
2 Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM ; MOT

Parameter | Name:

C00587 | Status - fan control

Data type: BITFIELD_8

Index: 23988

d

= 5DB4

h

Value is bit-coded:

Bit 0 Heatsink fan ON
Bit 1 Integral fan ON
Bit 2 Heatsink fan status 1
Bit 3 Heatsink fan status 2
Bit 4 Integral fan status
Bit 5 Reserved
Bit 6 Reserved
Bit 7 Reserved

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00588 | Resp. to t. sensor drive failure

Data type: UNSIGNED_32

Index: 23987

d

= 5DB3

h

Response, to error/failure of temperature sensor for heatsink/temperature inside the controller
Selection list

(Lenze setting printed in bold)

0 No response
1 Error
5 Warning

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00589 | Resp. to CPU temp. > C00126

Data type: UNSIGNED_32

Index: 23986

d

= 5DB2

h

Response, if CPU temperature on the control card > variable limit temperature (

C00126

).

Selection list

(Lenze setting printed in bold)

0 No response
1 Error
5 Warning

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT