C02639, C02640, C02642 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 631: C02639/1, C02639/2, C02639/3, C02639/4, C02639/5, C02639/6, C02639/7

Advertising
background image

L

Firmware 1.37 - 09/2006

631

9400 HighLine | Parameter setting & configuration

Parameter reference

Parameter list | C02639

C02639

C02640

C02642

Parameter | Name:

C02639 | Manual control: Dig. signals

Data type: UNSIGNED_32

Index: 21936

d

= 55B0

h

Display of the boolean signals of the basic function "

Manual jog

" (LS_ManualJog).

Selection list

0 FALSE
1 TRUE

Subcodes

Information

C02639/1

MAN_bEnable

C02639/2

MAN_bJogPositive

C02639/3

MAN_bJogNegative

C02639/4

MAN_bActivateJogSpeed2

C02639/5

MAN_bReleaseLimitSwitch

C02639/6

MAN_bEnabled

C02639/7

MAN_bActive

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C02640 | Ref. mode

Data type: UNSIGNED_32

Index: 21935

d

= 55AF

h

Basic function "

Homing

"

Selection list

(Lenze setting printed in bold)

0 cw_Rn_TP
1 ccw_Rn_TP
2 cw_Lp_ccw_Rn_TP
3 ccw_Ln_cw_Rn_TP
4 cw_Rp_ccw_Rn_TP
5 ccw_Rp_cw_Rn_TP
8 cw_TP
9 ccw_TP

10 cw_Lp_ccw_TP
11 ccw_Ln_cw_TP
12 cw_Lp
13 ccw_Ln
14 cw_Trq_Lim
15 ccw_Trq_Lim

100 Set home pos. directly

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C02642 | Home position

Data type: INTEGER_32

Index: 21933

d

= 55AD

h

Basic function "

Homing

"

Setting range

(min. value | unit | max. value)

Lenze setting

-214748.3647

Unit

214748.3647 0.0000 Unit

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 10000

Advertising