Parameter reference

Parameter list | C00378

C00378

C00379

C00381

C00382

C00383

Parameter | Name:

C00378 | CAN boot-up delay - operational

Data type: UNSIGNED_16

Index: 24197

d

= 5E85

h

Time after mains switching after which the CAN NMT master sends the "Start remote node" telegram to the bus.

• The delay time is only used when the master bit is activated (

C00352

) and the controller has been restarted.

Setting range

(min. value | unit | max. value)

Lenze setting

0

ms

65535 3000 ms

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00379 | Service code

Data type: UNSIGNED_8

Index: 24196

d

= 5E84

h

This code is used internally by the controller and must not be overwritten by the user!

Parameter | Name:

C00381 | CAN heartbeat producer time

Data type: UNSIGNED_16

Index: 24194

d

= 5E82

h

Time interval at which the device sends a heartbeat telegram with its device status to the bus.

• Selection of the "node guarding" monitoring function deactivates the "heartbeat" monitoring function.
Setting range

(min. value | unit | max. value)

Lenze setting

0

ms

65535 0 ms

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00382 | CAN guard time

Data type: UNSIGNED_16

Index: 24193

d

= 5E81

h

After the set guard time multiplied by the life time factor (

C00383

), a node guarding telegram must have been

received.
Setting range

(min. value | unit | max. value)

Lenze setting

0

ms

65535 0 ms

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00383 | CAN life time factor

Data type: UNSIGNED_8

Index: 24192

d

= 5E80

h

The life time factor multiplied by the guard time (

C00382

) results in the time in which a node guarding telegram

must have been received.
Setting range

(min. value | unit | max. value)

Lenze setting

0

255 0

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT