9400 HighLine | Parameter setting & configuration

I/O terminals

Monitoring function "State bus"

128

Firmware 1.37 - 09/2006

L

7.6.1

Detecting the current status

Use the output DIGIN_bStateBusIn of the system block

LS_DigitalInput

to display the

current state bus status. If an error occurs, the output DIGIN_bStateBusIn is set to TRUE.

7.6.2

Setting the state bus to the status "Error"

If the input DIGOUT_bStateBusOut of the system block

LS_DigitalOutput

is set to TRUE, the

state bus is set to "Error" and all connected devices start their pre-programmed response.

LS_DigitalInput

DIGIN_bStateBusIn

CONTROL

GE

24E

SB

X2

LS_DigitalOutput

DIGOUT_bStateBusOut

GE

24E

SB

X2

CONTROL