9400 HighLine | Parameter setting & configuration

TAs for positioning tasks

TA "Multi-purpose positioning" | Signal configuration of the output ports

408

Firmware 1.37 - 09/2006

L

13.2.13

Signal configuration of the output ports

If required, the preset signal configuration of the output ports can be easily reconfigured

per parameter setting of the assigned multiplexer parameters.

"LPortAxisOut1" output port
The output port LPortAxisOut1 is intended for the connection with a following axis.

Signal (Lenze setting)

Output port

Signal configuration

Axis status word

• The bits are assigned as in case of status word 1/2.

• Application-specific signals can be supplemented.

Drive ready  Axis status word bit 00

C03120/1

FALSE  Axis status word bit 01

C03120/2

Operation enabled  Axis status word bit 02

C03120/3

Error is active.  Axis status word bit 03

C03120/4

FALSE  Axis status word bit 04

C03120/5

Quick stop active  Axis status word bit 05

C03120/6

Drive is ready to start  Axis status word bit 06

C03120/7

Warning active  Axis status word bit 07

C03120/8

FALSE  Axis status word bit 08

C03120/9

FALSE  Axis status word bit 09

C03120/10

FALSE  Axis status word bit 10

C03120/11

Motor control limited  Axis status word bit 11

C03120/12

FALSE  Axis status word bit 12

C03120/13

FALSE  Axis status word bit 13

C03120/14

FALSE  Axis status word bit 14

C03120/15

FALSE  Axis status word bit 15

C03120/16

Setpoints for horizontal communication

Motor torque  Axis-Port Out 1

C03124/1

Motor speed  Axis-Port Out 2

C03124/2