Motor interface

Parameter setting | Special characteristic for motor temperature sensor

5.4.2

Special characteristic for motor temperature sensor

If required you can select and activate a special characteristic for the motor temperature

sensor.

r

The special characteristic is selected with two grid points which are to be set in

C01191

and

C01192

. Both grid points define a line which is extrapolated to the right and to the

left.

r

The special characteristic is activated by setting

C01190

= "1".

r

In the Lenze setting the special characteristic is defined as follows:

[5-14] Lenze setting of the special characteristic

5.4.3

Motor temperature monitoring

If the winding temperature detected by the motor temperature sensor exceeds the limit

value set in

C00121

, the reaction set in

C00584

is activated as advance warning.

r

In the Lenze setting the reaction "Warning" occurs if the winding temperature exceeds

120 °C.

r

As soon as the fixed limit value of 150 °C is exceeded, the reaction set in

C00583

is

activated (default setting: "Fault").

r

If an open circuit is detected in the motor temperature sensor, the reaction set in

C00594

(default setting: "Fault") is activated.

r

Grid pointn

C01191/1

= 25°C

C01192/1

= 1000 Ω

r

Grid pointo

C01191/2

= 150°C

C01192/2

= 2225 Ω

0

1000

2225

0

150

W

°C

25

Œ



Note!

By selecting a motor from the motor catalog the parameters

C01190

,

C01191

and

C01192

are overwritten!

Note!

By setting

C00583

= "0" the monitoring response and the temperature

correction is switched off within the motor control (identification and

parameter correction)
This setting is e.g. sensible if no realisable winding temperature signal is

available.