9400 HighLine | Parameter setting & configuration

Parameter reference

Parameter list | C00375

578

Firmware 1.37 - 09/2006

L

C00375

C00376

C00377

Parameter | Name:

C00375 | CAN SDO client Rx identifier

Data type: BITFIELD_32

Index: 24200

d

= 5E88

h

Identifier which serves to reach the assigned SDO client.

• Setting bit 31 (0x8nnnnnnn) deactivates the corresponding SDO client channel (see DS301V402).

• The client channels need not be parameterised right now. Their functionality will only be required when using

the Gateway services.

Value is bit-coded:

Information

Bit 0 COB-ID bit 0

• Bit 0 ... 10: COB-ID

• Bit 11 ... 30: Reserved

• Bit 31: SDO invalid

... ...

Bit 31 SDO invalid

Subcodes

Lenze setting

Information

C00375/1

0x80000000

SDO client channel 1 RX ... 10 RX

C00375/...
C00375/10

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00376 | CAN SDO client Tx identifier

Data type: BITFIELD_32

Index: 24199

d

= 5E87

h

Identifier with which the assigned SDO client is able to transmit.

• Setting bit 31 (0x8nnnnnnn) deactivates the corresponding SDO client channel (see DS301V402).

• The client channels need not be parameterised right now. Their functionality will only be required when using

the Gateway services.

Value is bit-coded:

Information

Bit 0 COB-ID bit 0

• Bit 0 ... 10: COB-ID

• Bit 11 ... 30: Reserved

• Bit 31: SDO invalid

... ...

Bit 31 SDO invalid

Subcodes

Lenze setting

Information

C00376/1

0x80000000

SDO client channel 1 TX ... 10 TX

C00376/...
C00376/10

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00377 | CAN SDO server node address

Data type: UNSIGNED_8

Index: 24198

d

= 5E86

h

Node address of the server with which the SDO client communicates via the selected client channel.

• The client functionality need not be activated.

• Activation of the CAN SDO client channel requires an entry (see DS301V402).
Setting range

(min. value | unit | max. value)

1

127

Subcodes

Lenze setting

Information

C00377/1

1

Remote server node address for SDO client channel 1 ...

10

C00377/...
C00377/10

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT