1 master value source: virtual master, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 306

Advertising
background image

9400 HighLine | Parameter setting & configuration

TAs for interconnection via electrical shaft

TA "Electronic gearbox" | Selection of master value source and output

306

Firmware 1.37 - 09/2006

L

12.2.4.1

Master value source: Virtual master
If the "Virtual master" is selected as master value source, the master value is created in the

TA and transmitted via a bus system or the digital frequency output to the other slave

drives.

r

Parameter setting: Tab Application parameter  Dialog level Overview  Virtual

master

r

Configuration: Tab FB editor  FB VirtualMaster

Parameters

Lenze setting

Value Unit

C03565

Operating mode

Continuous operation

C03568/1

Master speed 1

500.0000 Unit/t

C03568/2

Master speed 2

0.1000 Unit/t

C03569/1

Speed inching right

50.0000 Unit/t

C03569/2

Speed inching left

25.0000 Unit/t

C03570/1

Inching ramp

0.010 s

C03570/2

Continuous operation ramp

1.000 s

C03570/3

Stop ramp

1.000 s

Control/setpoint inputs of the function

Signal configuration

Lenze setting

Control/setpoint input

(Multiplexer parameters)

FALSE  VMas master shaft STOP1

C03058/1

C03016  Activate master function

C03058/3

C03017  VMas inching positive

C03058/4

C03018  VMas inching negative

C03058/5

FALSE  VMas start continuous operation

C03058/7

FALSE  VMas 2. master speed

C03058/8

0  VMaster handwheel

C03056