9400 HighLine | Parameter setting & configuration

Basic drive functions

Positioning | System block "LS_Positioner"

182

Firmware 1.37 - 09/2006

L

POS_bEnabled

C02679/7

| BOOL

Status output "Basic function is enabled"

TRUE Positioning via the control inputs is possible.

• The enable input POS_bEnable is set to TRUE and the controller is

in the function state "Positioning active".

POS_bActive

C02679/8

| BOOL

Status output "Basic function is active"

TRUE Positioning is active (the drive axis is moving).

POS_bDone

C02679/9

| BOOL

Status output "Basic function is completed"

TRUE Positioning is completed.

• The profile is executed and no sequence profile is defined.

POS_bInTarget

C02679/10

| BOOL

Status output "Target position reached"

FALSE Positioning is still active or has been aborted.

TRUE The current position setpoint has reached the target position.

POS_dnSetPos_p

C02678/1

| DINT

Current position setpoint in [increments]

• Absolute positioning: point of reference is the home position.

• Relative positioning: point of reference is the starting position of the current

profile.

POS_dnProfileTarget_p

C02678/2

| DINT

Target position of the current profile in [increments]

• Absolute positioning: point of reference is the home position.

• Relative positioning: point of reference is the starting position of the current

profile.

POS_dnProfileSpeed_s

C02676

| DINT

Current setpoint speed of the current profile as speed in [rpm]

• In consideration of a speed override.

POS_-

dwActualProfileNumber

C02674

| DWORD

Profile number (1 .... 100) of the current profile