3 master value trimming, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 311

Advertising
background image

L

Firmware 1.37 - 09/2006

311

9400 HighLine | Parameter setting & configuration

TAs for interconnection via electrical shaft

TA "Electronic gearbox" | Operating mode "Electronic gearbox"

12.2.5.3

Master value trimming

[12-15] "Master value trimming" function in the signal flow (schematic diagram)

This function serves to adjust the master value.

r

Parameter setting: Tab Application parameter  Dialog level Overview  Electronic

gearbox  Master value trimming

r

Configuration: Tab FB editor  FB Trimming

n

Master value with clutch

o

Master value with trimming

M

v

Slave

Real master/

Virtual master

v

t

Dv

C03006 = 0

Œ



Parameters

Lenze setting

Value Unit

C03674

Master value with clutch

- Unit/t

C03026

Activate trimming

Deactivated

C03027

Positive trimming

Inactive

C03028

Negative trimming

Inactive

C03685

Positive speed

400.0000 Unit/t

C03686

Negative speed

-200.0000 Unit/t

C03687

Acceleration ramp

1.000 s

C03688

Deceleration ramp

1.000 s

C03689

Disable ramp

1.000 s

C03690

Master value with trimming

- Unit/t

Control inputs of the function

Signal configuration

Lenze setting

Control input

(Multiplexer parameters)

C03026  Activate trimming

C03058/15

C03027  Positive trimming

C03058/17

C03028  Negative trimming

C03058/18

Advertising