3 state "device is ready to switch on, State "device is ready to switch on, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 47

Advertising
background image

L

Firmware 1.37 - 09/2006

47

9400 HighLine | Parameter setting & configuration

Drive interface

Device states

4.5.3

State "Device is ready to switch on"

The controller is in this device state directly after the initialisation is completed and no DC-

bus voltage is applied yet.

r

The bus systems are running and the terminals and encoders are evaluated.

r

The monitoring modes are active.

r

The controller can be parameterised and device commands can be executed in a limited

way.

r

The application is basically executable.

r

The function of the user task can be used.
– Condition: The application has started (status display in

C02108

).

r

The basic drive functions cannot be used yet.

r

There are two options for a change from the "Device is ready to switch on" state to the

"Device is switched on" state:
– Auto restart enabled after mains connection (

C00142

= "1").

– Auto restart inhibited after mains connection (

C00142

= "0") and controller

inhibited.

Auto start option 1: Auto restart enabled after mains connection

r

The following figure shows the status change for the automatic start option 1 (Lenze

setting) as a function of the controller inhibit:

[4-12] State change when auto restart is enabled (C00142 = "1")

LED DRIVE READY

LED DRIVE ERROR

Display in

C00183

OFF

141: Device is ready to switch on




Controller pulses are inhibited

Controller pulses are enabled

n
o

With controller inhibit during power-on

Without controller inhibit during power-on

RFR

Œ

0

1

RFR

RFR

RFR

t

t



Initialisation

Switched on

Operation

Ready to switch on

Operation

Initialisation

Switched on

Ready to switch on