Dfin (mxi1): z-/z track error [0x00990002, Can module (mxi1): bus-off [0x009d0000, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 501

Advertising
background image

L

Firmware 1.37 - 09/2006

501

9400 HighLine | Parameter setting & configuration

Diagnostics & error analysis

Error messages of the operating system

DFIN (MXI1): Z-/Z track error [0x00990002]

DFIN (MXI1): Enable/lamp control signal error [0x00990003]

DFIN (MXI1): Supply cannot be corrected anymore [0x00990004]

DFOUT (MXI1): Maximum frequency reached [0x00990005]

CAN module (MXI1): Bus-off [0x009d0000]

Response (Lenze setting printed in bold)

Setting:

C13040

(; Adjustable response)

;

None … System fault : Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information

Cause

Remedy

Digital frequency extension module in MXI1:

Interruption (open circuit) of the signal cable for track Z.

• Check signal cable for track Z.

• Check encoder.

Response (Lenze setting printed in bold)

Setting:

C13041

(; Adjustable response)

;

None … System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked : Warning ; Information

Cause

Remedy

Digital frequency extension module in MXI1:

Interruption (open circuit) of the signal cable for the

"Enable" signal or no "Enable" signal available.

• Check signal cable for "Enable" signal.

• Check encoder.

Response (Lenze setting printed in bold)

Setting:

C13042

(; Adjustable response)

;

None … System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked : Warning ; Information

Cause

Remedy

Digital frequency extension module in MXI1: The

encoder voltage controlled by the digital frequency input

has reached the voltage limit.

Check encoder.

Response (Lenze setting printed in bold)

Setting:

C13080

(; Adjustable response)

;

None … System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked : Warning ; Information

Cause

Remedy

Digital frequency extension module in MXI1: Limit

frequency at the digital frequency output reached.

• The digital frequency has reached the limit value set

in

C013053

.

Check set limit value.

Response (Lenze setting printed in bold)

Setting:

C13595

(; Adjustable response)

;

None … System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning : Information

Cause

Remedy

CANopen communication module in MXI1: "Bus-off"

state

• Too many faulty telegrams received.

• Cable defective (e.g. loose contact).

• Two nodes with the same ID.

• Remove fault (e.g. EMC).

• Remove loose contact, screw down adapter.

• Assign different node IDs.

Advertising