Program download is faulty [0x006a0001, Error during input and output update [0x006a0002, New application loaded [0x006a0003 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 458: User task 1: overflow [0x006a0004, User task 2: overflow [0x006a0005, User task 3: overflow [0x006a0006, 9400 highline | parameter setting & configuration

Advertising
background image

9400 HighLine | Parameter setting & configuration

Diagnostics & error analysis

Error messages of the operating system

458

Firmware 1.37 - 09/2006

L

Program download is faulty [0x006a0001]

Error during input and output update [0x006a0002]

New application loaded [0x006a0003]

User task 1: Overflow [0x006a0004]

User task 2: Overflow [0x006a0005]

User task 3: Overflow [0x006a0006]

Response (Lenze setting printed in bold)

…

None … System fault : Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

Transmission of the application to the controller is faulty

(checksum error).

Repeat transmission.

Response (Lenze setting printed in bold)

…

None … System fault : Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

Internal error

Mains switching. Transmit the application to the

controller again.

• Please contact Lenze, if the problem occurs again.

Response (Lenze setting printed in bold)

…

None … System fault … Fault … Trouble … Quick stop by trouble … Warning locked … Warning : Information

Cause

Remedy

Application has been changed by transmission from the

engineer or loading from the memory module.

- (Information only)

Response (Lenze setting printed in bold)

…

None … System fault : Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

Program runtime in user task 1 is too high.

Reduce program runtime by means of:

• Omitting functions (e.g. by reducing the number of

active FBs).

• Optimising the computing time of specific functions

Response (Lenze setting printed in bold)

…

None … System fault : Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

Program runtime in user task 2 is too high.

See remedy for "

Overflow of user task 1

".

Response (Lenze setting printed in bold)

…

None … System fault : Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

Program runtime in user task 3 is too high.

See remedy for "

Overflow of user task 1

".