Firmware 1.37 - 09/2006

149

9400 HighLine | Parameter setting & configuration

Basic drive functions

Standard stop | Parameter setting

9.2.1

Parameter setting

r

Parameterisation dialog in the »Engineer«: Tab Application parameter  Dialog level

Overview  All basic functions  Stop

r

Short overview of parameters for standard stop :

Parameter setting of stop

[9-2]

Deceleration time referred to the motor reference speed

[9-3]

Deceleration time referred to the current speed

[9-4]

S-shaped deceleration ramp through selection of a relative S-ramp time

Parameters

Information

C02610

Deceleration time for stop

C02611

S-ramp time for stop

C02612

Ref. for decel. time of stop

r

The deceleration time set in

C02610

for stop refers to a speed variation

from the motor reference speed

(

C00011

) to standstill, i. e. the

deceleration is constant.

n

t

C00011

C02610

r

When

C02612

is set = "1", the

deceleration time refers to the current

speed, i. e. the braking time is constant.

C02610

n

t

C00011

r

Through the entry of a S-ramp time in

C02611

an S-shaped deceleration

ramp for jerk reduction can be set. This

prolongs the total time to standstill by

the selected S-ramp time.

r

Braking time at motor reference speed

or

C02612

= "1":

n

t

C00011

n

t

C00011

C02612 = 0

C02612 = 1

C02610 + C02611

C02610 [s] C02611 [s]

+