413808 and 413812—Address Translation Unit (PCI Express)

Intel

®

413808 and 413812 I/O Controllers in TPER Mode

Developer’s Manual

October 2007

258

Order Number: 317805-001US

3.6

PCI Express Messages

PCI Express defines a new message mechanism that is used to communicate outside of

the normal Memory, I/O, and Configuration Spaces. The messages received and

initiated by 4138xx vary depending on whether the device is acting as a root complex

or an endpoint. All the messages defined in the PCI Express specification and 4138xx’s

actions are listed in

Table 125

.

Table 125. Supported Message Types (Sheet 1 of 2)

Message

Description/ Comments

RC or

End

Point

Comment

Standard Messages initiated by SRL

ERR_COR

Signal detection of a correctable error

to Root Complex

RC, End

Point

Set appropriate bit in ATUISR

RC: Also log in PCI Express Error

Source Identification Register

ERR_NONFATAL

Signal detection of an uncorrectable

error Root Complex

ERR_FATAL

Signal detection of a fatal error Root

Complex

PM_Active_State_NAK

Rejection of request to enter a low

power state from an End Point or

Upstream Port.

RC

PME_Turn_Off

a

Notification of pending turn-off of link

clock and power

RC

Generated from PEMCSR.

PM_PME

b

PME message conveying the ID of the

PME originator

End

Point

PME_TO_Ack

Acknowledge turn-off of link clock and

power

End

Point

Automatically generated on

receipt of PME_Turn_Off

message

Assert_INTx

Assert INTx virtual signal

End

Point

Generate to reflect signals from

Interrupt Controller.

Deassert_INTx

De-assert INTx virtual signal

End

Point

Set_Slot_Power_Limit

Set Slot Power Limit in Upstream Port RC

Generated due to write to Slot

Capabilities register or anytime

Link transitions from non-DL_Up

status to a DL_Up status.

Vendor Defined Message

Type 0/1

Vendor Specific Message. It is used by

devices to communicate with SRL

device core.

RC,

End

Point

Generated from Outbound

Vendor Message register.

Attention_Indicator_X

These messages are issued by the

root port to change the indicator on

the device

RC

Generate due to change in

indicator control bits in Slot

Control Register

Power_Indicator_X

These messages are issued by the

root port to change the indicator on

the device

RC

Attention_Button_Pressed Issued by endpoint when button

pressed on device

End

Point

Generated from PEMCSR