Intel

®

413808 and 413812—Clocking and Reset

Intel

®

413808 and 413812 I/O Controllers in TPER Mode

Developer’s Manual

October 2007

776

Order Number: 317805-001US

ATUE

The ATUE does not participate in the IB Reset handshake.

However the affect on the ATUE varies depending on the

PCIE_RC#

strap.

End Point Mode (

PCIE_RC#

= 1):

An Internal Bus Reset does not reset the ATUE when

operating as an endpoint.

Root Complex Mode (

PCIE_RC#

= 0)

No special requirements, the ATUE can be reset at anytime.

This reset includes the configuration space.

Note:

While the ATUX must take special requirements to

prevent corrupting the PCI bus, the PCI Express link

is a point-to-point interface so no precautions need

to be taken before resetting the link.

End Point Mode:

No affect on ATUE logic.

All ATUX Configuration Registers

retain their current values.
Root Complex Mode:

Entire ATUX is reset, including

Configuration Registers. However,

sticky bits in the Configuration

Space are not reset.

MCU

MCU cannot be reset until the powerfail sequence completes. Clear all interrupts and reset MMRs

to default value

MU

MU can be reset at any time

PCI Configuration registers and

MSI-X memory registers are

preserved.

All other MMRs and logic are reset

to their default values.

All Other

Units

No special requirements

Clear all interrupts and reset MMRs

and logic to default value

Table 514. Internal Bus Reset Summary (Sheet 2 of 2)

Unit

Preparation for Reset

Reset Status

Advertising