7.3.7.2

Bridge South Internal Bus Interface Error

The following conditions may be encountered by the Bridge South Interface:

• Master Abort on the South Internal Bus interface. This condition may happen when

the bridge attempts an address request on the south internal bus and the request

is not claimed by any target. The bridge would log the error as a master abort.

— For a write request, the bridge logs the master abort error condition and

discard the write data.

— For a read request, the Bridge logs the master abort. In addition, the Bridge

completes the read completion as follows: it indicates to the initiating agent on

the north internal bus that it encountered an error by performing a target abort

during the read completion.

• Address Request Error on the south internal bus interface. This condition may

happen when a target on the south internal bus detected an error during the

address request. For example, the target may indicate that the byte-count is out of

range or the target detected an address parity error.

— For a write request, the bridge logs the address request error condition and

discard the write data.

— For read request, the Bridge logs the address request error. In addition, the

Bridge completes the read completion as follows: it indicates to the initiating

agent on the north internal bus that it encountered an error by performing a

target abort during the read completion.

• Target Abort on the south internal bus. This condition may occur when a target

claimed a previously issued read request, but is unable to return the read

completion data. The bridge would log the error as a target abort.

— The Bridge logs the target abort. In addition, the Bridge completes the read

completion as follows: it indicates to the initiating agent on the north internal

bus that it encountered an error by performing a target abort during the read

completion. Address Parity Error on the south internal bus. This condition may

occur when the Bridge south interface is acting as a target and either observes

AERR asserted by another target on the south internal bus, or detects an

address parity error while claiming an address request.