Programmable Blink Patterns

Each of the SGPIO output signal supports two programmable blink patterns that can be

selected using the

Table 328, “SGPIO Output Data Select Register[0:7] x -

SGODSR[0:7]x” on page 484

. The blink rate generator is clocked using an 8 Hz clock

and allows the user to program a low and a high duration time using two 4-bit fields

located in the

Table 322, “SGPIO Programmable Blink Register x - SGPBRx” on

page 476

. The shortest low/high duration time that can be program is 125 ms and the

longest low/high duration time that can be programmed is 2 seconds. The shortest

blink rate period is 250 ms and the longest blink rate period is 4 seconds.