H3C Technologies H3C Intelligent Management Center User Manual

Page 368

Advertising
background image

354

To view RMON invalid alarm details for the selected device from the Device Details page:

1.

Click the RMON link located under the Device Management section of the right navigation tree on
the selected device's Device Details page.

2.

Click the Alarm Group tab located at the top of the RMON Alarm Group page.

3.

Click Invalid Item located at the top of the Alarm Group table.
IMC displays all RMON invalid alarm entries in the Invalid RMON Alarm list on the RMON Alarm
Group page.

Alarm group list

Index: Contains unique index values for the associated alarm.

Item: Contains the metric that is measured by this alarm instance.

Port: Contains the port name/description for the associated interface.

Sampling Type: Identifies whether or not the value of the sample to be measured should be
evaluated in an absolute sense or in a comparative sense. Absolute sampling measures the current
sampling value accumulated since the system started up. Comparative sampling, also referred to as

delta sampling, measures the value by subtracting the last absolute sampling value from the current

absolute sampling value. The sampling interval is also a factor in comparative or delta sampling.

Generally, delta or comparative sampling is selected.

Interval (second): Contains the amount, in seconds, of time between polls.

Current Sampling Value: Contains the value for the most recent sample.

Startup Type: Contains the type of threshold being used by the alarm instance. Three alarm startup
types are available: allowing rising and falling alarms, allowing rising alarms and allowing falling

alarms.

Rising Threshold: Contains the rising threshold value. A rising threshold defines the value that the
sampled value must exceed in order to generate an alarm.

Falling Threshold: Contains the falling threshold value. A falling threshold defines the value that the
sampled value must fall below in order to generate an alarm.

Rising Event Index: Contains the index for a rising event.

Falling Event Index: Contains the index for a falling event.

Owner: Contains the name of the owner of the RMON statistics collection that is configured when
you add the interface to Alarm Group collection.

Status: Indicates whether or not the alarm instance is active.

Reason for Null: Contains the cause for the null value for the associated alarm group entry.
If the Invalid RMON Alarm list contains multiple entries, the following navigational aids may
appear:

{

Click

to page forward in the Invalid RMON Alarm list.

{

Click

to page forward to the end of the Invalid RMON Alarm list.

{

Click

to page backward in the Invalid RMON Alarm list.

{

Click

to page backward to the front of the Invalid RMON Alarm list.

4.

Click 8, 15, 50, 100, or 200 from the right side of the main pane to configure how many items per
page you want to view.
You can only view devices that they have been granted management access to.