You can select devices by Device IP address, by Custom Views, by Network Segment or by a

combination of the three. For more information, see "

Selecting devices by IP address

",

"

Selecting devices by custom view

", or "

Selecting devices by network segment

."

You can select devices by using either the View or Advanced query option. See "

Adding

devices by View

" and "

Adding devices by Advanced query

."

You can add devices using one or more of the Selected Devices options. For example, you can
enter the IP address of one device and an IP address range, and groups defined by custom

view. The alarm notification rule forwards alarms for all devices or groups configured in the

rule.

8.

Select which error conditions trigger alarm forwarding from the Concerned Alarms list. Operators
can select all conditions or only a specified subset of conditions that trigger alarm forwarding.

{

All Alarms: With this option, all alarms configured in IMC generate alarm forwarding if the
alarm condition is triggered.

{

Selected Alarms: With this option, only the alarms you select in alarm notification generate
alarm forwarding if the alarm condition is triggered. Further, you can select which alarms

trigger alarm forwarding.

9.

To configure which conditions to send notifications for:

a.

Click Select located to the right of the Concerned Alarms field. The Select Alarm dialog box
appears.

b.

In the Select Alarm dialog box, locate the Enterprise MIB that contains an object or condition
that you want to alarm on.

c.

To expand your view of the MIB, click on the arrow key next to the MIB that contains an

object or condition that you want to alarm on.

d.

Click the Expand all icon located in the upper right corner of the Select Alarm dialog box

to expand your view to display all MIBs, or
Use the query function located at the top of the Select Alarm dialog box to locate the object that

you want alarm on.

10.

Enter one or more of the following search criteria:

{

Trap Name: Enter the object name for the trap you want to locate in the Trap Name field.

{

Trap OID: Enter the Object ID for the trap in the Trap OID field.

{

Enterprise Name: Enter a partial or complete name for the Enterprise MIB you want to locate in
the Enterprise Name field.

{

Enterprise OID: Enter a partial or complete Enterprise ID for the MIB you want to locate in the

Enterprise OID field.

11.

Click Query to submit your search criteria. The results of your query display in the dialog box.
Optional: Click Reset to clear your query criteria and to restore the full list of MIBs and traps.

12.

Click the checkbox to select a MIB object that you want to alarm on.

13.

Click OK.
It may take a while for the Select Alarm dialog box to close. When the box closes, it updates the
Concerned Alarms field with the configured object or alarm condition.
You can click on multiple checkboxes to select multiple objects or conditions to alarm on. Each
alarm condition is listed in the Concerned Alarms field below the list.

14.

Click Parameter Setting located to the right of the Concerned Alarm field, the Set Alarm Parameter
dialog box appears with all alarms with parameters listed.